Product name : CHINA FACTORY STAINLESS STEEL VERTICAL PIPELINE SEWAGE PUMP GWP. GWP SERIES SEWAGE PUMP CHINA SUPPLIER, FACTORY AND MANUFACTURER
Product No. : 2022330171451
Details:
GWP type non-clogging pipeline sewage pump product overview
GWP type non-clogging pipeline sewage pump is a new generation of pump products successfully developed on the basis of the introduction of foreign advanced technology and combined with the use characteristics of domestic water pumps. Features. It has a unique effect in discharging solid particles and long-fiber waste. This series of pumps adopts a unique impeller structure and a new type of machine seal, which can effectively transport the medium containing solids and long fibers. Compared with the traditional impeller, the impeller of the pump adopts the form of single flow channel or double flow channel. It is similar to a curved pipe with the same cross-section and has very good flow capacity. High efficiency, the impeller has been tested for dynamic and static balance, so that the pump has no vibration during operation.
The hydraulic performance of the pump is advanced and mature, and all the performance indicators of the product have reached the relevant standards.
The hydraulic performance of the pump is advanced and mature, and all the performance indicators of the product have reached the relevant standards.
GWP type non-clogging pipeline sewage pump
GWP type non-clogging pipeline sewage pump product features
1. The pump is a vertical single-suction single-stage centrifugal pump. The center line of the inlet and outlet is on the same horizontal line, and the inlet and outlet flanges are the same, so the installation and disassembly are very convenient, the floor space is small, and it can be installed in any pipeline like a valve. position.
2. The pump and the motor are directly connected to the same axis, which is a mechatronic product with compact structure and stable performance.
3. The large flow channel is designed with anti-clogging hydraulic components, which greatly improves the ability of dirt to pass through, and can effectively pass through fibrous substances that are 5 times the diameter of the pump and solid particles with a diameter of about 50% of the diameter of the pump.
4. The design is reasonable, the matching motor is reasonable, the efficiency is high, and the energy saving effect is remarkable.
5. The mechanical seal is made of hard wear-resistant tungsten carbide, which is durable and wear-resistant, and can make the pump run safely and continuously for more than 8,000 hours.
6. The hydraulic performance is advanced, the whole machine has high efficiency and low operating noise.
7. A protective cover is added to the fan blade end of the motor, and the whole machine can be placed outdoors to work without the need for a machine room, which can save a lot of infrastructure costs.
8. Use it within the range of the use head to ensure that the motor is not overloaded.
GWP type non-clogging pipeline sewage pump product use
1. Discharge of seriously polluted wastewater from factories and businesses.
2. Drainage system of urban sewage treatment plant.
3. Sewage drainage stations in residential areas.
4. Civil air defense system drainage station.
5. Sewage discharge from hospitals and hotels.
6. Municipal engineering and construction sites.
7. Exploration and mining supporting machines.
8. Farmland irrigation in rural biogas digesters.
9. The water supply device of the waterworks.
GWP type non-clogging pipeline sewage pump operating conditions
1. The temperature of the medium should not exceed +40℃, the intermittent use (less than 5 minutes) should be +70℃, the weight should be 1.0~1.3kg/dm3, and the PH value should be within the range of 5~9.
2. For pumps without internal gravity circulation cooling system, the exposed liquid level of the motor part should not exceed 1/2.
3. Under normal circumstances, the pump must be used within the range of use head to ensure that the motor is not overloaded. If it needs to be used within the full head range, it should be specified separately when ordering, so that the manufacturer can manufacture it.
4. The motor current shall not exceed the rated current of the motor during operation.
GWP type non-clogging pipeline sewage pump
GWP type unblocked pipeline sewage pump before starting
1. First check whether the external fasteners are loose during transportation.
2. Check whether the power supply voltage meets the requirements of the motor nameplate.
3. Turn on the power supply and try to turn it to see if the impeller turns in the direction indicated on the pump. If the direction is reversed, switch any two-phase wire in the cable. The time for trial rotation should not be too long to avoid burning the seal. .
4. Install the pump and start it up. So that the pump foot screws can be installed.
2. Check whether the power supply voltage meets the requirements of the motor nameplate.
3. Turn on the power supply and try to turn it to see if the impeller turns in the direction indicated on the pump. If the direction is reversed, switch any two-phase wire in the cable. The time for trial rotation should not be too long to avoid burning the seal. .
4. Install the pump and start it up. So that the pump foot screws can be installed.
GWP Type Unblocked Pipeline Sewage Pump
1. The insulation resistance of the motor winding to the casing should be checked before the pump is used. If it is lower than 0.5 megohm, the stator must be dried, and the insulation resistance can be increased before use.
2. If the gap between the impeller and the oil seal at the inlet of the pump body exceeds 2mm, the wear-resistant oil seal should be replaced.
3. When the pump seal leaks, the seal should be replaced in time. When replacing, the static seal should be installed flat, and then the dynamic seal should be installed on the shaft.
4. When replacing the impeller, use a puller to pull it out, and do not beat it with a hammer, so as not to damage the axis.
Common failure reasons
1. There is no water, the weight and particle size of the pumped liquid are too high; the liquid flow channel is blocked; the impeller is turned wrong; the bar material is drawn into the impeller and is stuck; the height of the pipe outlet exceeds the rated lift height.
2. Insufficient flow and low lift. The voltage is low, the impeller is turned wrongly or the wear-resistant seal is worn; the heavy particle size of the liquid is too high.
3. The insulation resistance is low, the surrounding environment is humid, and the mechanical seal is seriously leaking.
Performance parameter table
Diameter
mm |
model | Flow m3/h |
head m |
Speed r/min |
Power
kw |
---|---|---|---|---|---|
25 | GWP6-10-0.75 | 6 | 10 | 2900 | 0.75 |
GWP6-15-1.1 | 6 | 15 | 2900 | 1.1 | |
32 | GWP8-12-0.75 | 8 | 12 | 2900 | 0.75 |
GWP12-15-1.5 | 12 | 15 | 2900 | 1.1 | |
40 | GWP10-10-0.75 | 10 | 10 | 2900 | 0.75 |
GWP8-15-1.1 | 8 | 15 | 2900 | 1.1 | |
GWP12-15-1.5 | 12 | 15 | 2900 | 1.5 | |
GWP15-20-2.2 | 15 | 20 | 2900 | 2.2 | |
50 | GWP20-7-0.75 | 20 | 7 | 2900 | 0.75 |
GWP10-10-0.75 | 10 | 10 | 2900 | 0.75 | |
GWP10-12-1.1 | 10 | 12 | 2900 | 1.1 | |
GWP25-10-1.5 | 25 | 10 | 2900 | 1.5 | |
GWP20-15-1.5 | 20 | 15 | 2900 | 1.5 | |
GWP15-15-1.5 | 15 | 15 | 2900 | 1.5 | |
GWP15-20-2.2 | 15 | 20 | 2900 | 2.2 | |
GWP15-18-2.2 | 15 | 18 | 2900 | 2.2 | |
GWP15-25-2.2 | 15 | 25 | 2900 | 2.2 | |
GWP27-15-2.2 | 27 | 15 | 2900 | 2.2 | |
GWP30-14-2.2 | 30 | 14 | 2900 | 2.2 | |
GWP42-9-2.2 | 42 | 9 | 2900 | 2.2 | |
GWP30-10-2.2 | 30 | 10 | 2900 | 2.2 | |
GWP20-22-3 | 20 | 22 | 2900 | 3 | |
GWP25-18-3 | 25 | 18 | 2900 | 3 | |
GWP15-30-3 | 15 | 30 | 2900 | 3 | |
GWP25-20-4 | 25 | 20 | 2900 | 4 | |
GWP40-15-4 | 40 | 15 | 2900 | 4 | |
GWP20-30-5.5 | 20 | 30 | 2900 | 5.5 | |
GWP20-40-7.5 | 20 | 40 | 2900 | 7.5 | |
GWP25-35-7.5 | 25 | 35 | 2900 | 7.5 | |
GWP30-40-7.5 | 30 | 40 | 2900 | 7.5 | |
65 | GWP25-10-1.5 | 25 | 10 | 2900 | 1.5 |
GWP35-7-2.2 | 35 | 7 | 2900 | 2.2 | |
GWP30-10-2.2 | 30 | 10 | 290 | 2.2 | |
GWP25-15-2.2 | 25 | 15 | 2900 | 2.2 | |
GWP37-13-3 | 37 | 13 | 2900 | 3 | |
GWP30-22-4 | 30 | 22 | 2900 | 4 | |
GWP40-15-4 | 40 | 15 | 2900 | 4 | |
GWP25-30-5.5 | 25 | 30 | 2900 | 5.5 | |
GWP32-25-5.5 | 32 | 25 | 2900 | 5.5 | |
GWP40-30-7.5 | 40 | 30 | 2900 | 7.5 | |
GWP30-40-7.5 | 30 | 40 | 2900 | 7.5 | |
GWP30-45-11 | 30 | 45 | 2900 | 11 | |
GWP35-50-15 | 35 | 50 | 2900 | 15 | |
GWP35-60-18.5 | 35 | 60 | 2900 | 18.5 | |
80 | GWP40-7-2.2 | 40 | 7 | 2900/1450 | 2.2 |
GWP43-13-3 | 43 | 13 | 2900 | 3 | |
GWP40-15-4 | 40 | 15 | 2900 | 4 | |
GWP50-20-5.5 | 50 | 20 | 2900 | 5.5 | |
80 | GWP40-25-5.5 | 40 | 25 | 2900 | 5.5 |
GWP30-30-5.5 | 30 | 30 | 2900 | 5.5 | |
GWP65-25-7.5 | 65 | 25 | 2900 | 7.5 | |
GWP50-20-7.5 | 50 | 20 | 2900 | 7.5 | |
GWP30-40-7.5 | 30 | 40 | 2900 | 7.5 | |
100 | GWP85-10-4 | 85 | 10 | 1450/2900 | 4 |
GWP50-20-5 | 50 | 20 | 1450/2900 | 5.5 | |
GWP65-15-5.5 | 65 | 15 | 1450/2900 | 5.5 | |
GWP100-10-7.5 | 100 | 10 | 1450/2900 | 7.5 | |
GWP85-15-7.5 | 85 | 15 | 1450/2900 | 7.5 | |
GWP80-20-7.5 | 80 | 20 | 1450/2900 | 7.5 | |
GWP100-15-7.5 | 100 | 15 | 1450/2900 | 7.5 | |
GWP100-25-11 | 100 | 25 | 1450/2900 | 11 | |
GWP100-30-15 | 100 | 30 | 1450/2900 | 15 | |
GWP100-35-18.5 | 100 | 35 | 1450/2900 | 18.5 | |
150 | GWP145-9-7.5 | 145 | 9 | 1450 | 7.5 |
GWP110-15-7.5 | 110 | 15 | 1450 | 7.5 | |
GWP200-7-11 | 200 | 7 | 1450 | 11 | |
GWP200-10-15 | 200 | 10 | 1450 | 15 | |
GWP180-20-18.5 | 180 | 20 | 1450 | 18.5 | |
GWP180-25-22 | 180 | 25 | 1450 | 22 | |
GWP200-20-22 | 200 | 20 | 1450 | 22 | |
GWP240-20-30 | 240 | 20 | 1450 | 30 | |
GWP200-25-30 | 200 | 25 | 1450 | 30 | |
GWP150-35-37 | 150 | 35 | 1450 | 37 | |
200 | GWP300-7-11 | 300 | 7 | 980 | 11 |
GWP250-11-15 | 250 | 11 | 1450 | 15 | |
GWP250-15-18.5 | 250 | 15 | 1450 | 18.5 | |
GWP400-10-22 | 400 | 10 | 1450 | 22 | |
GWP300-15-22 | 300 | 15 | 1450 | 22 | |
GWP400-13-30 | 400 | 13 | 1450 | 30 | |
GWP400-18-37 | 400 | 18 | 1450 | 37 | |
GWP400-20-45 | 400 | 20 | 1450 | 45 | |
GWP400-25-55 | 400 | 25 | 1450 | 55 | |
250 | GWP600-9-30 | 600 | 9 | 980 | 30 |
GWP600-12-37 | 600 | 12 | 980 | 37 | |
GWP600-15-45 | 600 | 15 | 1450 | 45 | |
GWP600-20-55 | 600 | 20 | 1450 | 55 | |
GWP600-25-75 | 600 | 25 | 1450 | 75 | |
300 | GWP800-12-45 | 800 | 12 | 1450 | 45 |
GWP800-15-55 | 800 | 15 | 1450 | 55 | |
GWP800-20-75 | 800 | 20 | 1450 | 75 | |
GWP950-20-90 | 950 | 20 | 1450 | 90 | |
GWP1000-25-110 | 1000 | 25 | 1450 | 110 | |
350 | GWP950-14-55 | 950 | 14 | 980 | 55 |
GWP1260-12-75 | 1260 | 12 | 980 | 75 | |
GWP1450-14-90 | 1450 | 14 | 980 | 90 | |
GWP1200-20-110 | 1200 | 20 | 980 | 110 |
Related Products: